Vel Workhandling Euipments specializes in design,
fabrication, supply, erection and commissioning
of innumerable water spray systems for Cement
Mills, Grate Coolers, Down Comer Ducts, Gas Conditioning
Towers, etc to cement Industries in India.
|
VEL
CEMENT MILL WATER SPRAY SYSTEM |
|
APPLICATION
During the process of finish
grinding of clinker, lot of heat is generated
inside the cement mill. The heat generated in
excess has to be dissipated so that mill discharge
temperature is kept at a desired level (around
90-120°C) to prevent the deterioration of the
quality of cement. The increase in temperature
beyond 125°C leads to dehydration of gypsum which
changes the property of setting of cement. The
decrease in temperature below 90°C leads to wet
clogging of gypsum and the cement strength is
affected.
Internal water cooling in a cement mill serves
to maintain the mill outlet temperature constant
at preset values.
VEL Cement Mill Water Spray System is the advanced
method of temperature control in cement mills
which results in enhanced cement quality.
|
 |
SYSTEM
DESCRIPTION
VEL Cement Mill Water Spray
System comprises of complete set of pumps, valves,
spray nozzles. instruments etc & all relevant
accessories, assembled as one unit making it user-friendly
and easy to install.
Water Cooling in the Cement Mill
is accomplished by injecting and evaporating water
at the outlet / inlet end of the mill. The water
vapour is removed from the mill together with
the ventilation air, which must be so ample that
the temperature does not drop below the dew point
anywhere in the pipes, dedusting filter, etc after
the mill.
The system ensures precise control
of temperature in both the chambers of cement
mill by regulating the volume of injected water
through motorised control valves. The design of
the injection nozzles and the compressed air used
for atomization gives a very good turn down ratio
in the entire range of water flow regulation.
When the water injection is disconnected, compressed
air purging keeps the injection nozzles clean.
The system may be interfaced and operated through
your existing PLC/DCS or may be provided with
a standalone control panel.
|
 |
| PDF
BROCHURES |
VEL
GRATE COOLER WATER SPRAY SYSTEM |
APPLICATION
In Cement Industries, VEL Grate Cooler Water Spray
System is used for cooling the vent gas for any
of these purposes:
|
To
increase the efficiency of ESP by reducing
fugitive dust emission. |
|
To
reduce the power consumption of the vent outlet
fan. |
|
To
maintain a slightly more negative pressure
at vent outlet thus contributing in reducing
fugitive emission. |
|
To
reduce the temperature so that the upstream
conveying equipments could be designed for
lower temperatures thus reducing the capital
cost. |
|
To
cool the clinker directly so that the inlet
temperature to cement mill is within controllable
limits. |
|
To
control the depth of the clinker bed both
to avoid grate burn-out due to low bed depth,
and to avoid stalling the cooler fans due
to excessive bed depth. |
|
To
limit fluctuations in the secondary air
temperature as this can upset the kiln temperature
profile and adversely affect clinker quality.
|
|
 |
SYSTEM DESCRIPTION
VEL Cooler water spray system comprises of complete set of skid mounted pumping & valve train system along with spray nozzles & relevant accessories. All necessary instruments, control valves etc are provided. All closed loop controls, sequence of operation, alarms & Safety interlocks are provided. The system may be interfaced to your existing PLC/DCS or may be provided with a standalone control panel.
DESIGN CRITERIA
The purpose or application, dimensions of the Grate Cooler, the height of the clinker bed, the overall gas flow, the gas temperature, the clinker temperature profile, number of nozzles needed and the height at which the lances are to fixed in the cooler compartment, the degree of cooling required put together determines the type of is spray system to be used,that is:
· Compressed air atomized water spray system
· Spillback water spray system
· Fogjet / Multicone water spray system
· Flatjet water spray system |
 |
|
| PRINCIPLE OF OPERATION
In VEL Grate Cooler Water Spray System, the temperature of the stream of gas / clinker is cooled in three stages:
1) Heating of the injected liquid to the boiling point temperature corresponding to the system pressure.
2) Conversion of part of the liquid into a gaseous state by evaporation of the liquid.
3) Superheating of the evaporated liquid.
We can also provide Grate Cooler Water Spray System especially for Direct Cooling of Clinker bed. This is normally required when the cooler is operated above its designed capacity.
We design, manufacture, supply to achieve your ultimate goal.
|
| PDF
BROCHURES |
|
|
|
| | | |
|
© 2003-05 Vel Engineering Services. All Rights
Reserved Webpartner: Niftysoft
Solution, India.
|
|
|
|